LKX-1200-6.25 T1+T2 1200V 6.25kA DC Type 1+2 PV Surge Protective Device

The LKX-1200V T1+T2 is a surge protection device designed to protect low-voltage electrical systems from lightning-induced surges. It features fast response time, high discharge capacity, and easy installation. Ideal for use in industrial control cabinets, communication systems, and power distribution panels.

Request a Quote

PRODUCTS DETAILS

Specification LKX-1200-6.25
SPD classification according to EN61643-31 / IEC61643-31 Type 1 + Type 2 / Class I + Class II
Max. continuous operating d.c. voltage Ucpv 1200V
Lightning impulse current (10/350μs) Iimp 6.25kA
Nominal discharge current (8/20μs) In 20kA
Max. discharge current (8/20μs) Imax 40kA
Residucal current Ipe(DC) <0.02mA
Specific energy W/R 9.76kJ/Ω
Voltage protection level [(DC+/DC-)→PE] Up ≤4.5kV
Short-circuit current rating Iscpv 10kA
Response time tA ≤25ns
Operating temperature range Tu -40℃-80℃
Operating state / fault indication green / red
Cross-section area (Min.) 4mm²
Cross-section area (Max.) 35mm²
For mounting on 35mm Din rail
Enclosure material Thermoplastic UL94-V0
Degree of protection IP20
Order code LKX12003625
Order code (with remote signal) LKX12003625-1

Features:

Thermal disconnect device for each individual connector

Normal discharge current (8/20us) In: 20kA

Mechanical status indication for the individual surge protective device module

High energy varistors.

With or without floating remote indication contact

Application:

LKX Surge protective device, protect against lightning surge voltages in solar system (photovoltaic power supply system).

Used for surge protection of electrical components in any other DC circuit.

These units must be installed in parallel on the DC networks to be protected and provide common and different modes protection.

It is suitable for surge protection of DC power supply line equipment of solar power generation system.

Installation and maintenance:

Installed in parallel at the interface of LPZ1 zone and subsequent zones: power controller, power converter, etc.

When the surge arrester is installed under the required conditions, it does not require long-term maintenance, but only routine maintenance. If the color of the visible alarm window changes to red (fault) during use, it indicates that the surge protector is damaged and needs to be repaired or replaced.